Modular
design allows for interchangeable components. Complete
sensor consists of sensor block, power block, and
optional logic modules and/or quick disconnect cables.
Sensor block configuration includes opposed mode,
diffuse mode, retroreflective (polarized is optional),
convergent mode, fiber optic (glass and plastic),
AC-coupled, analog, and ultrasonic. Power blocks are
available in AC or DC operation. DC models contain
bi-modal outputs for sinking or sourcing applications.
Logic modules offer timing functions such as; on delay,
off delay, and delayed one-shot.
The Banner Omni-Beam also contains the patented D.A.T.A.
diagnostic display system. These LED lights warn of
problems with high / low voltage, high / low gain
signal, good vs. poor contrast, and more... |
|